Extract Technology has developed an innovative aseptic isolator system designed to operate in a sterile environment with a requirement for specific temperature and humidity control.
HEPA filtration provides the system with positive operating pressure and air change rates to guarantee an ISO-5 environment. Stepping away from traditional re-circulatory air flow, air is returned through cavities in the walls and glass doors on both sides of the isolator to achieve an even exhaust re-circulating airflow pattern, and laminar airflow at the point of fill.
The aseptic isolator's sterile environment is achieved through the integration of a hydrogen peroxide biodecontamination gas generator to eradicate the risk of bacterial contamination.